+86 21 59830621
                      sales@hbtetech.com
                      English

                      Passive Attenuator

                      HBTE passive attenuators include continuous variable attenuators, step attenuators, and fixed attenuators. We supply RF attenuator impedance specifications are 50 ohms and 75 ohms. There are 2.92mm, N, and SMA connectors of these series of passive Attenuators. The RF dB attenuation of attenuators ranges from 0 dB to 99 dB. Our passively Attenuators range in frequency from DC to 40 GHz. The product range includes low-power to high-power attenuators with power processing ranges from 1 watt to 500 watts.


                      RF attenuators can be shipped from HBTE enterprises' ISO 9001:2008 quality system certified manufacturing factory after you placed your order. HBTE enterprises have the most complete varieties and specifications of RF and microwave components inventory. Excellent technical support and after-sales service can help you at any time.


                      Passive Attenuator

                      Types of Passive Attenuator

                      NOProduct model

                      Average

                      power

                      (W)

                      Frequency

                      Range(GHz)

                      Attenuation

                      value (dB)

                      Connector

                      1HBTE-CA002-6-XX-S-92DC~61-9/10/20/30SMA-M/F
                      2HBTE-CA002-12.4-XX-S-92DC~12.41-9/10/20/30SMA-M/F
                      3HBTE-CA002-18-XX-S-92DC~181-9/10/20/30SMA-M/F
                      4HBTE-CA002-6-XX-N-182DC~61-9/10/20/30N-M/F
                      5HBTE-CA002-12.4-XX-N-182DC~12.41-9/10/20/30N-M/F
                      6HBTE-CA002-18-XX-N-182DC~181-9/10/20/30N-M/F
                      7HBTE-CA005-6-XX-S-155DC~61-9/10/20/30SMA-M/F
                      8HBTE-CA005-12.4-XX-S-155DC~12.41-9/10/20/30SMA-M/F
                      9HBTE-CA005-18-XX-S-155DC~181-9/10/20/30SMA-M/F
                      10HBTE-CA005-6-XX-S-175DC~61-9/10/20/30SMA-M/F
                      11HBTE-CA005-12.4-XX-S-175DC~12.41-9/10/20/30SMA-M/F
                      12HBTE-CA005-18-XX-S-175DC~181-9/10/20/30SMA-M/F
                      13HBTE-CA005-6-XX-S-235DC~61-9/10/20/30SMA-M/F
                      14HBTE-CA005-12.4-XX-S-235DC~12.41-9/10/20/30SMA-M/F
                      15HBTE-CA005-18-XX-S-235DC~181-9/10/20/30SMA-M/F
                      16HBTE-CA005-6-XX-N-235DC~61-9/10/20/30N-M/F
                      17HBTE-CA005-12.4-XX-N-235DC~12.41-9/10/20/30N-M/F
                      18HBTE-CA005-18-XX-N-235DC~181-9/10/20/30N-M/F
                      19HBTE-CA010-6-XX-S-1510DC~61-9/10/20/30SMA-M/F
                      20HBTE-CA010-12.4-XX-S-1510DC~12.41-9/10/20/30SMA-M/F
                      21HBTE-CA010-18-XX-S-1510DC~181-9/10/20/30SMA-M/F
                      22HBTE-CA010-6-XX-S-1710DC~61-9/10/20/30SMA-M/F
                      23HBTE-CA010-12.4-XX-S-1710DC~12.41-9/10/20/30SMA-M/F
                      24HBTE-CA010-18-XX-S-1710DC~181-9/10/20/30SMA-M/F
                      25HBTE-CA010-6-XX-S-3210DC~61-9/10/20/30SMA-M/F
                      26HBTE-CA010-12.4-XX-S-3210DC~12.41-9/10/20/30SMA-M/F
                      27HBTE-CA010-18-XX-S-3210DC~181-9/10/20/30SMA-M/F
                      28HBTE-CA010-6-XX-N-3210DC~61-9/10/20/30N-M/F
                      29HBTE-CA010-12.4-XX-N-3210DC~12.41-9/10/20/30N-M/F
                      30HBTE-CA010-18-XX-N-3210DC~181-9/10/20/30N-M/F
                      31HBTE-CA030-6-XX-S-38.830DC~61-9/10/20/30SMA-M/F
                      32HBTE-CA030-12.4-XX-S-38.830DC~12.41-9/10/20/30SMA-M/F
                      33HBTE-CA030-18-XX-S-38.830DC~181-9/10/20/30SMA-M/F
                      34HBTE-CA030-6-XX-N-38.830DC~61-9/10/20/30N-M/F
                      35HBTE-CA030-12.4-XX-N-38.830DC~12.41-9/10/20/30N-M/F
                      36HBTE-CA030-18-XX-N-38.830DC~181-9/10/20/30N-M/F
                      37HBTE-CA050-6-XX-S-38.850DC~61-9/10/20/30SMA-M/F
                      38HBTE-CA050-8-XX-S-38.850DC~81-9/10/20/30SMA-M/F
                      39HBTE-CA050-6-XX-N-38.850DC~61-9/10/20/30N-M/F
                      40HBTE-CA050-8-XX-N-38.850DC~81-9/10/20/30N-M/F
                      41HBTE-CA050-6-XX-N-5530DC~61-9/10/20/30N-M/F
                      42HBTE-CA050-12.4-XX-N-5530DC~12.41-9/10/20/30N-M/F
                      43HBTE-CA050-18-XX-N-5530DC~181-9/10/20/30N-M/F
                      44HBTE-CA050-6-XX-S-5530DC~61-9/10/20/30SMA-M/F
                      45HBTE-CA050-12.4-XX-S-5530DC~12.41-9/10/20/30SMA-M/F
                      46HBTE-CA050-18-XX-S-5530DC~181-9/10/20/30SMA-M/F
                      47HBTE-CA100-6-XX-S-55100DC~61-9/10/20/30SMA-M/F
                      48HBTE-CA100-8-XX-S-55100DC~81-9/10/20/30SMA-M/F
                      49HBTE-CA100-6-XX-N-55100DC~61-9/10/20/30N-M/F
                      50HBTE-CA100-8-XX-N-55100DC~81-9/10/20/30N-M/F
                      51HBTE-CA150-6-XX-N-55150DC~61-9/10/20/30N-M/F
                      52HBTE-CA150-8-XX-N-55150DC~81-9/10/20/30N-M/F
                      53HBTE-CA150-4-XX-N-75X60150DC~41-9/10/20/30N-M/F
                      54HBTE-CA200-4-XX-N-75X60200DC~41-9/10/20/30N-M/F
                      55HBTE-CA250-4-XX-N-100X60250DC~41-9/10/20/30N-M/F
                      56HBTE-CA300-4-XX-N-100X60300DC~41-9/10/20/30N-M/F
                      57HBTE-CA350-4-XX-N-100X80350DC~41-9/10/20/30N-M/F
                      58HBTE-CA400-4-XX-N-100X80400DC~41-9/10/20/30N-M/F
                      59HBTE-CA450-4-XX-N-100X80450DC~41-9/10/20/30N-M/F
                      60HBTE-CA500-4-XX-N-100X80500DC~41-9/10/20/30N-M/F


                      FAQs of HBTE Passive Attenuators

                      What is the main function of fixed attenuator

                      (1) Adjust the size of the signal in the circuit;


                      (2) In the comparison measurement circuit, the attenuation value of the network under test can be read directly;


                      (3) If some circuits require a relatively stable load impedance, an attenuator can be inserted between the circuit and the actual load impedance to buffer the change of impedance.


                      If I exceed the maximum input level, will I burn out the fixed attenuator?

                      This is not recommended as it may cause data distortion or burn down attenuators.

                      All of HBTE fixed attenuators are tested and specified at 50Ω impedance, can I use them at 75Ω?

                      It is not recommended. If you need key specifications for the 75 Ω system, please contact our salesman. Our engineers will redesign the internal components for you to meet specific requirements.

                      Start Now
                      Email us with inquiries or use our contact data. We would be happy to answer your questions.
                      What's new at HBTE
                      Proudly supporting customers in 127 + countries, across 30 market segments and industries
                      Hangzhou Yongxie Technology Co., Ltd.
                      HBTE develops, produces and markets a wide range of RF capital devices for industry, infrastructure operators, education and research institutions customers.
                      国产亚洲视频在线观看网址,精品?久久?国语,亚洲成在人线AV无码,丰满的少妇被猛烈进入白浆视频